Phoenix SACC-MINFR/M16FR/M12 Series Industrial Circular Connectors Selection Guide

Opening: Specialized Connection Solutions for Compact & High-Density Industrial Field Devices

The Phoenix SACC-MINFR/M16FR/M12 series is a portfolio of industrial-grade circular connectors tailored for compact field devices, high-core-count signal/power transmission, and M12-standard industrial interfaces. Covering compact MINFR (3-5 core), high-density M16FR (14 core), and versatile M12 (2-8 core) sub-series—including basic accessories, signal/ethernet (MSX/MSD), power (MST/MSS), and fiber (MSL) variants—these connectors feature IP67 protection (when mated), shielded (SH) EMI resistance, and compatibility with PROFINET/ETH industrial protocols. Widely used in sensor/actuator wiring, industrial Ethernet networks, and compact control cabinet interconnection, they ensure reliable transmission in harsh factory and outdoor environments.


I. Core Advantages of the Series

  1. Multi-Scenario Interface Compatibility
    • M12 standard interface: Industry-universal M12 connectors support 2-8 core signal/power/ethernet transmission, compatible with global industrial sensors/PLCs;
    • MINFR compact design: 3-5 core small-size connectors for space-constrained devices (e.g., miniaturized sensors/auxiliary actuators);
    • M16FR high-density: 14-core M16 FR connector for complex hybrid signal/power transmission in limited cabinet space.
  2. Industrial-Grade Reliability
    • IP67 ingress protection (when mated) for dust/water resistance, suitable for workshop floors and outdoor field installations;
    • SH shielded variants (suffix SH) for EMI suppression, ensuring signal integrity near inverters/motors;
    • Gold-plated contacts for low contact resistance and ≥10,000 mating cycles, reducing maintenance frequency.
  3. Diverse Functional Customization
    • Protocol compatibility: MSX/MSD series support PROFINET (ETH suffix) and PN (power-neutral) coding for Siemens control systems;
    • Power/signal separation: MST/MSS series (2PE/3PE) for dedicated power transmission, MSD/MSX for signal/ethernet;
    • Cable flexibility: PG7/9/11/13 thread glands for different cable diameters (2.5mm² max), matching field wiring needs.
  4. Plug-and-Play Installation
    • Tool-free locking nuts (SCO NUT) for quick field assembly;
    • Pre-configured SET kits (M12-SET) for one-stop wiring of 2.5-3.5mm cables;
    • DIN rail or panel-mounted options, compatible with Phoenix control cabinet infrastructure.

II. Product Classification & Detailed Parameter Table

The series is categorized by interface type and functional focus (MINFR Compact Series, M16FR High-Density Series, M12 Basic Accessories, M12 Functional Connectors) with sub-variants based on core count, protocol, and installation specifications.

1. SACC-MINFR Series (Compact FR Interface Connectors)

3-5 core compact connectors with PG9/11/13 glands, designed for space-constrained field and cabinet-internal devices.

Part Number Complete Model Core Parameters Key Features Application Scenario
1456307 SACC-MINFR-5CON-PG13/2,5 Core Count:5; Gland:PG13; Cable:2.5mm²; Interface:FR; Protection:IP67 5-core compact connector for 2.5mm² cables Compact 5-channel actuator power/signal connection (e.g., pharmaceutical equipment 5-group mini-solenoid valve wiring)
1456297 SACC-MINFR-5CON-PG11/2,5 Core Count:5; Gland:PG11; Cable:2.5mm²; Interface:FR 5-core connector for 2.5mm² PG11 cables 5-channel sensor signal in narrow control cabinets (e.g., laboratory precision instrument 5-point data transmission)
1521517 SACC-MINFR-5CON-PG 9 Core Count:5; Gland:PG9; Cable:Standard; Interface:FR 5-core compact connector for PG9 small cables 5-channel small-cable device connection (e.g., workshop auxiliary 5-group indicator light wiring)
1521494 SACC-MINFR-4CON-PG 9 Core Count:4; Gland:PG9; Interface:FR 4-core compact PG9 connector 4-channel mini-sensor signal transmission (e.g., compact conveyor belt 4-point proximity sensor wiring)
1521478 SACC-MINFR-3CON-PG 9 Core Count:3; Gland:PG9; Interface:FR 3-core ultra-compact PG9 connector 3-channel critical small-device control (e.g., emergency stop button 3-channel signal in mini-machinery)

2. SACC-M16FR Series (14-Core High-Density M16 Connectors)

14-core M16 FR connector for high-density hybrid signal/power transmission in complex control systems.

Part Number Complete Model Core Parameters Key Features Application Scenario
1500253 SACC-M16FR-14CON-M Core Count:14; Gender:Male; Interface:M16 FR; Protection:IP67 14-core high-density M16 male connector Complex 14-channel device interconnection (e.g., robotic workstation 14-group end-effector sensor/power hybrid transmission)

3. SACC-M12 Basic Accessories (Cable Kits & Mechanical Components)

M12-standard installation accessories and cable kits for quick field deployment and connector fixation.

Part Number Complete Model Core Parameters Key Features Application Scenario
1436505 SACC-M12-SET/2,5-3,5 Cable Range:2.5-3.5mm²; Kit:Complete wiring set; Interface:M12 Pre-configured M12 cable kit for 2.5-3.5mm cables One-stop M12 wiring for workshop sensors/actuators (no on-site cable cutting/crimping)
1551493 SACC-M12-SCO PLUG Type:M12 SCO plug; Interface:Standard M12; Protection:IP67 M12 SCO standard plug for signal/power Replacement plug for M12 connector maintenance (e.g., damaged sensor M12 plug replacement)
1432460 SACC-M12-SCO NUT L 90 Type:90° angled locking nut; Compatibility:M12 SCO; Material:Anti-corrosion metal 90° angled nut for space-constrained M12 installation M12 connector installation in narrow device cavities (e.g., machinery side-mount sensor 90° wiring)
1552243 SACC-M12-SCO NUT Type:Straight locking nut; Compatibility:M12 SCO; Feature:Tool-free Straight tool-free nut for quick M12 assembly Field M12 connector rapid installation (e.g., outdoor sensor M12 nut fastening without tools)

4. SACC-M12 Functional Connectors (Signal/Power/Ethernet/Fiber)

The core sub-series of M12 connectors, divided into MSX (8-core ethernet/signal), MST/MSS (2PE/3PE power), MSL (4-core fiber), and MSD (4-core signal/power/control) variants.

4.1 MSX Series (8-Core M12 Signal/Ethernet Connectors)

8-core M12 connectors for industrial ethernet (ETH) and PN-coded signal transmission, with shielded (SH) EMI protection.

Part Number Complete Model Core Parameters Key Features Application Scenario
1411044 SACC-M12MSX-8QO SH PN Core Count:8; Coding:QO; Feature:SH shielded + PN power-neutral; Protocol:Industrial signal 8-core shielded PN-coded signal connector 8-channel PROFINET PN sensor network (e.g., automotive assembly line 8-group vision camera signal)
1411043 SACC-M12MSX-8QO SH ETH Core Count:8; Coding:QO; Feature:SH shielded + ETH; Protocol:Industrial Ethernet 8-core shielded industrial ethernet connector 8-channel workshop ethernet data transmission (e.g., 8-group AGV positioning module ETH connection)
1422844 SACC-M12MSX-8CT-CL SH Core Count:8; Coding:CT; Feature:SH shielded + CL locking; Protocol:Control signal 8-core shielded control signal connector 8-channel PLC control signal transmission (e.g., packaging machine 8-group actuator control wiring)

4.2 MST/MSS Series (2PE/3PE M12 Power Connectors)

2/3-core M12 power connectors for dedicated PE (protective earth) power transmission, with PG7/9/11 cable glands.

Part Number Complete Model Core Parameters Key Features Application Scenario
1404643 SACC-M12MST-3PECON-PG11-M Core Count:3PE; Gland:PG11; Gender:Male; Feature:Power connection 3PE M12 male power connector for PG11 cables 3PE power supply for M12 field actuators (e.g., workshop 3PE solenoid valve power wiring)
1027467 SACC-M12MSS-3PECT-CM SH Core Count:3PE; Coding:CT; Feature:SH shielded + CM locking; Type:Signal-power hybrid 3PE shielded hybrid power/signal connector 3PE power + control signal for high-interference actuators (e.g., inverter-proximal 3PE motor power)
1404641 SACC-M12MSS-3PECON-PG11-M Core Count:3PE; Gland:PG11; Gender:Male 3PE M12 power connector for PG11 cables General 3PE M12 power distribution (e.g., 3PE sensor power supply in workshop)
1107268 SACC-M12MSS-3PECON-PG 9-M Core Count:3PE; Gland:PG9; Gender:Male 3PE M12 power connector for PG9 small cables 3PE power for compact M12 devices (e.g., laboratory 3PE instrument power wiring)
1419639 SACC-M12MSS-2PECON-PG 9-M Core Count:2PE; Gland:PG9; Gender:Male 2PE M12 power connector for PG9 cables 2PE power supply for low-power M12 sensors (e.g., 2PE proximity sensor power in conveyor systems)

4.3 MSL Series (4-Core M12 Fiber Connectors)

4-core M12 fiber (FEPL) connectors for optical signal transmission in high-interference environments.

Part Number Complete Model Core Parameters Key Features Application Scenario
1080235 SACC-M12MSL-4FEPL-CL SH Core Count:4; Type:FEPL fiber; Feature:SH shielded + CL locking 4-core shielded M12 fiber connector 4-channel fiber signal transmission in high-interference areas (e.g., inverter room 4-group fiber sensor data)
1151368 SACC-M12MSL-4FEPL-CL Core Count:4; Type:FEPL fiber; Feature:CL locking 4-core M12 fiber connector (non-shielded) 4-channel fiber signal in low-interference cabinets (e.g., control cabinet internal fiber module wiring)

4.4 MSD Series (4-Core M12 Signal/Power/Control Connectors)

4-core M12 connectors for general signal (Q), power (PL), control (CT), and cable gland (CON) applications, with rich coding and shielding options.

Part Number Complete Model Core Parameters Key Features Application Scenario
1411068 SACC-M12MSD-4QO SH PN Core Count:4; Coding:QO; Feature:SH shielded + PN; Protocol:Signal 4-core shielded PN-coded signal connector 4-channel PROFINET PN sensor signal (e.g., chemical plant 4-group pressure sensor data)
1411066 SACC-M12MSD-4QO SH ETH Core Count:4; Coding:QO; Feature:SH shielded + ETH; Protocol:Ethernet 4-core shielded industrial ethernet connector 4-channel M12 ethernet device connection (e.g., workshop 4-group HMI ETH wiring)
1404401 SACC-M12MSD-4Q SH PN WL Core Count:4; Coding:Q; Feature:SH shielded + PN + WL waterproof; Protocol:Signal 4-core waterproof PN-coded signal connector Outdoor 4-channel PN sensor signal (e.g., outdoor weather monitoring 4-point sensor data)
1554513 SACC-M12MSD-4Q SH PN Core Count:4; Coding:Q; Feature:SH shielded + PN 4-core PN-coded signal connector General 4-channel PN sensor wiring (e.g., workshop 4-group temperature sensor signal)
1543223 SACC-M12MSD-4Q SH Core Count:4; Coding:Q; Feature:SH shielded 4-core shielded signal connector 4-channel shielded sensor signal (e.g., high-interference 4-group proximity sensor data)
1424682 SACC-M12MSD-4PL SH PN Core Count:4; Type:PL power; Feature:SH shielded + PN 4-core PN-coded power connector 4-channel PN actuator power supply (e.g., 4-group solenoid valve PN power in packaging machines)
1422846 SACC-M12MSD-4CT-CM SH PN Core Count:4; Coding:CT; Feature:SH shielded + CM + PN; Type:Control 4-core PN-coded control signal connector 4-channel PLC control signal (e.g., robotic arm 4-group end-effector control wiring)
1521261 SACC-M12MSD-4CON-PG 9-SH Core Count:4; Gland:PG9; Feature:SH shielded; Type:Cable gland connector 4-core PG9 shielded cable gland connector 4-channel PG9 small-cable shielded connection (e.g., cabinet-internal 4-group module wiring)
1521258 SACC-M12MSD-4CON-PG 7-SH Core Count:4; Gland:PG7; Feature:SH shielded 4-core PG7 ultra-small cable shielded connector 4-channel ultra-small cable signal (e.g., laboratory 4-group precision sensor wiring)

III. Series Nomenclature Decoding

SACC-[Interface Series]-[Core Count/Type]-[Coding/Function]-[Gland/Feature Suffix]

  • SACC: Product series identifier (industrial circular connector for field device interconnection).
  • Interface Series:
    • MINFR = Compact FR-interface connector (3-5 core, space-constrained);
    • M16FR = 14-core M16 FR high-density connector;
    • M12 = M12-standard interface (sub-divided into MSX/MST/MSS/MSL/MSD by function);
      • MSX = 8-core M12 signal/ethernet;
      • MST/MSS = 2PE/3PE M12 power;
      • MSL = 4-core M12 fiber (FEPL);
      • MSD = 4-core M12 signal/power/control.
  • Core Count/Type:
    • XCON = X-core general connection (e.g., 5CON=5-core);
    • XPE = X-core protective earth power (e.g., 3PE=3-core power);
    • XQ/XQO = X-core signal (QO=special coding);
    • XPL = X-core power (PL=power contact);
    • XCT = X-core control signal (CT=control coding);
    • XFEPL = X-core fiber (FEPL=fiber optic).
  • Coding/Function:
    • QO/CT/PN = System coding (QO=legacy, CT=control, PN=PROFINET power-neutral);
    • ETH = Industrial Ethernet compatibility;
    • SH = Shielded (EMI protection);
    • CL/CM = Locking type (CL=click-lock, CM=mechanical lock);
    • WL = Waterproof (enhanced IP protection).
  • Gland/Feature Suffix:
    • PG7/9/11/13 = Cable gland size (matches cable diameter);
    • /2,5 = Supports 2.5mm² high-current cable;
    • L 90 = 90° angled accessory;
    • M = Male connector (female suffix omitted for standard);
    • SET = Complete cable installation kit.

IV. 3-Step Quick Selection Technique

Step 1: Select Series Based on Interface & Space Requirements

  • Compact 3-5 core devices (space-constrained): Choose MINFR series (1521478/1521517) for narrow cabinets/mini-devices.
  • 14-core high-density hybrid transmission: Opt for M16FR series (1500253) for complex robotic/workstation interconnection.
  • M12-standard field devices: Pick M12 functional series (MSX/MSD for signal/ethernet, MST/MSS for power, MSL for fiber).
  • M12 installation/deployment: Select M12 basic accessories (SET kit for wiring, SCO NUT for locking).

Step 2: Match Function to Transmission Demand

  • Industrial Ethernet/PROFINET: Choose MSX/MSD with ETH/PN suffix (1411043/1411066) for real-time control communication.
  • 2PE/3PE power supply: Select MST/MSS series (1404641/1419639) for dedicated PE power transmission.
  • Fiber signal (high-interference): Pick MSL series (1080235) with SH shielding for optical data transmission.
  • General 4-core signal/power: Opt for MSD series (1543223/1424682) based on coding (Q/PL/CT) needs.

Step 3: Choose Gland/Shielding for Installation Conditions

  • Cable diameter matching:
    • Ultra-small cables (≤φ7mm): PG7 gland (1521258);
    • Small cables (φ7-9mm): PG9 gland (1521261/1107268);
    • Medium cables (φ9-11mm): PG11 gland (1404641/1456297);
    • Large cables (φ11-13mm): PG13 gland (1456307) (supports 2.5mm² high-current).
  • High-interference environments: Select SH shielded variants (1080235/1411044) to suppress EMI.
  • Space-constrained installation: Pick 90° angled nuts (1432460) for side-mount device wiring.

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Automotive Robotics M12 8-core ETH camera + 4-core PN sensor + 3PE power 1411043 (MSX-8QO SH ETH) + 1411068 (MSD-4QO SH PN) + 1404641 (MSS-3PECON-PG11-M)
Chemical Plant Outdoor 4-core waterproof PN sensor + 4-core fiber signal + MINFR compact power 1404401 (MSD-4Q SH PN WL) + 1080235 (MSL-4FEPL-CL SH) + 1521517 (MINFR-5CON-PG9)
Packaging Machinery 4-core PL actuator power + M12 SET wiring kit + 90° angled nut 1424682 (MSD-4PL SH PN) + 1436505 (M12-SET/2,5-3,5) + 1432460 (M12-SCO NUT L90)
Laboratory Precision Control 4-core PG7 shielded sensor + 3-core MINFR control signal 1521258 (MSD-4CON-PG7-SH) + 1521478 (MINFR-3CON-PG9)

VI. Selection Pitfall Avoidance Guide

  1. Interface Compatibility Error: M12 PLC devices using MINFR connectors → Choose M12 functional series (MSD/MSX) to ensure mechanical/electrical matching and prevent connection failure.
  2. Shielding Neglect: Inverter-proximal signals using non-SH connectors → Select SH shielded variants (1080235/1411044) to suppress EMI and avoid signal distortion.
  3. Cable Gland Mismatch: 2.5mm² cables using PG7 glands → Pick PG11/13 glands with /2,5 suffix (1456307/1456297) to ensure cable fixation and IP67 protection.
  4. Protocol Incompatibility: PROFINET networks using non-PN/ETH connectors → Choose PN/ETH suffix models (1411068/1411043) to enable real-time control communication.
  5. Space Oversight: Narrow device cavities using straight nuts → Select 90° angled nuts (1432460) to avoid cable bending damage and improve installation fit.

Conclusion: Select the Right SACC Connector for Field Device Interconnection

The Phoenix SACC-MINFR/M16FR/M12 series provides targeted circular connection solutions for compact, high-density, and M12-standard industrial devices, covering signal, power, ethernet, and fiber transmission with diverse coding and shielding options. 

Phoenix SACC-MINFR/M16FR/M12 Series Industrial Circular Connectors Selection Guide

Created on:2025-12-12 11:08

News Dynamics

NEWS