Phoenix SACC-MINFR/M16FR/M12 Series Industrial Circular Connectors Selection Guide
Opening: Specialized Connection Solutions for Compact & High-Density Industrial Field Devices
The Phoenix SACC-MINFR/M16FR/M12 series is a portfolio of industrial-grade circular connectors tailored for compact field devices, high-core-count signal/power transmission, and M12-standard industrial interfaces. Covering compact MINFR (3-5 core), high-density M16FR (14 core), and versatile M12 (2-8 core) sub-series—including basic accessories, signal/ethernet (MSX/MSD), power (MST/MSS), and fiber (MSL) variants—these connectors feature IP67 protection (when mated), shielded (SH) EMI resistance, and compatibility with PROFINET/ETH industrial protocols. Widely used in sensor/actuator wiring, industrial Ethernet networks, and compact control cabinet interconnection, they ensure reliable transmission in harsh factory and outdoor environments.
I. Core Advantages of the Series
- Multi-Scenario Interface Compatibility
- M12 standard interface: Industry-universal M12 connectors support 2-8 core signal/power/ethernet transmission, compatible with global industrial sensors/PLCs;
- MINFR compact design: 3-5 core small-size connectors for space-constrained devices (e.g., miniaturized sensors/auxiliary actuators);
- M16FR high-density: 14-core M16 FR connector for complex hybrid signal/power transmission in limited cabinet space.
- Industrial-Grade Reliability
- IP67 ingress protection (when mated) for dust/water resistance, suitable for workshop floors and outdoor field installations;
- SH shielded variants (suffix SH) for EMI suppression, ensuring signal integrity near inverters/motors;
- Gold-plated contacts for low contact resistance and ≥10,000 mating cycles, reducing maintenance frequency.
- Diverse Functional Customization
- Protocol compatibility: MSX/MSD series support PROFINET (ETH suffix) and PN (power-neutral) coding for Siemens control systems;
- Power/signal separation: MST/MSS series (2PE/3PE) for dedicated power transmission, MSD/MSX for signal/ethernet;
- Cable flexibility: PG7/9/11/13 thread glands for different cable diameters (2.5mm² max), matching field wiring needs.
- Plug-and-Play Installation
- Tool-free locking nuts (SCO NUT) for quick field assembly;
- Pre-configured SET kits (M12-SET) for one-stop wiring of 2.5-3.5mm cables;
- DIN rail or panel-mounted options, compatible with Phoenix control cabinet infrastructure.
II. Product Classification & Detailed Parameter Table
The series is categorized by interface type and functional focus (MINFR Compact Series, M16FR High-Density Series, M12 Basic Accessories, M12 Functional Connectors) with sub-variants based on core count, protocol, and installation specifications.
1. SACC-MINFR Series (Compact FR Interface Connectors)
3-5 core compact connectors with PG9/11/13 glands, designed for space-constrained field and cabinet-internal devices.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1456307 | SACC-MINFR-5CON-PG13/2,5 | Core Count:5; Gland:PG13; Cable:2.5mm²; Interface:FR; Protection:IP67 | 5-core compact connector for 2.5mm² cables | Compact 5-channel actuator power/signal connection (e.g., pharmaceutical equipment 5-group mini-solenoid valve wiring) |
| 1456297 | SACC-MINFR-5CON-PG11/2,5 | Core Count:5; Gland:PG11; Cable:2.5mm²; Interface:FR | 5-core connector for 2.5mm² PG11 cables | 5-channel sensor signal in narrow control cabinets (e.g., laboratory precision instrument 5-point data transmission) |
| 1521517 | SACC-MINFR-5CON-PG 9 | Core Count:5; Gland:PG9; Cable:Standard; Interface:FR | 5-core compact connector for PG9 small cables | 5-channel small-cable device connection (e.g., workshop auxiliary 5-group indicator light wiring) |
| 1521494 | SACC-MINFR-4CON-PG 9 | Core Count:4; Gland:PG9; Interface:FR | 4-core compact PG9 connector | 4-channel mini-sensor signal transmission (e.g., compact conveyor belt 4-point proximity sensor wiring) |
| 1521478 | SACC-MINFR-3CON-PG 9 | Core Count:3; Gland:PG9; Interface:FR | 3-core ultra-compact PG9 connector | 3-channel critical small-device control (e.g., emergency stop button 3-channel signal in mini-machinery) |
2. SACC-M16FR Series (14-Core High-Density M16 Connectors)
14-core M16 FR connector for high-density hybrid signal/power transmission in complex control systems.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1500253 | SACC-M16FR-14CON-M | Core Count:14; Gender:Male; Interface:M16 FR; Protection:IP67 | 14-core high-density M16 male connector | Complex 14-channel device interconnection (e.g., robotic workstation 14-group end-effector sensor/power hybrid transmission) |
3. SACC-M12 Basic Accessories (Cable Kits & Mechanical Components)
M12-standard installation accessories and cable kits for quick field deployment and connector fixation.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1436505 | SACC-M12-SET/2,5-3,5 | Cable Range:2.5-3.5mm²; Kit:Complete wiring set; Interface:M12 | Pre-configured M12 cable kit for 2.5-3.5mm cables | One-stop M12 wiring for workshop sensors/actuators (no on-site cable cutting/crimping) |
| 1551493 | SACC-M12-SCO PLUG | Type:M12 SCO plug; Interface:Standard M12; Protection:IP67 | M12 SCO standard plug for signal/power | Replacement plug for M12 connector maintenance (e.g., damaged sensor M12 plug replacement) |
| 1432460 | SACC-M12-SCO NUT L 90 | Type:90° angled locking nut; Compatibility:M12 SCO; Material:Anti-corrosion metal | 90° angled nut for space-constrained M12 installation | M12 connector installation in narrow device cavities (e.g., machinery side-mount sensor 90° wiring) |
| 1552243 | SACC-M12-SCO NUT | Type:Straight locking nut; Compatibility:M12 SCO; Feature:Tool-free | Straight tool-free nut for quick M12 assembly | Field M12 connector rapid installation (e.g., outdoor sensor M12 nut fastening without tools) |
4. SACC-M12 Functional Connectors (Signal/Power/Ethernet/Fiber)
The core sub-series of M12 connectors, divided into MSX (8-core ethernet/signal), MST/MSS (2PE/3PE power), MSL (4-core fiber), and MSD (4-core signal/power/control) variants.
4.1 MSX Series (8-Core M12 Signal/Ethernet Connectors)
8-core M12 connectors for industrial ethernet (ETH) and PN-coded signal transmission, with shielded (SH) EMI protection.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1411044 | SACC-M12MSX-8QO SH PN | Core Count:8; Coding:QO; Feature:SH shielded + PN power-neutral; Protocol:Industrial signal | 8-core shielded PN-coded signal connector | 8-channel PROFINET PN sensor network (e.g., automotive assembly line 8-group vision camera signal) |
| 1411043 | SACC-M12MSX-8QO SH ETH | Core Count:8; Coding:QO; Feature:SH shielded + ETH; Protocol:Industrial Ethernet | 8-core shielded industrial ethernet connector | 8-channel workshop ethernet data transmission (e.g., 8-group AGV positioning module ETH connection) |
| 1422844 | SACC-M12MSX-8CT-CL SH | Core Count:8; Coding:CT; Feature:SH shielded + CL locking; Protocol:Control signal | 8-core shielded control signal connector | 8-channel PLC control signal transmission (e.g., packaging machine 8-group actuator control wiring) |
4.2 MST/MSS Series (2PE/3PE M12 Power Connectors)
2/3-core M12 power connectors for dedicated PE (protective earth) power transmission, with PG7/9/11 cable glands.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1404643 | SACC-M12MST-3PECON-PG11-M | Core Count:3PE; Gland:PG11; Gender:Male; Feature:Power connection | 3PE M12 male power connector for PG11 cables | 3PE power supply for M12 field actuators (e.g., workshop 3PE solenoid valve power wiring) |
| 1027467 | SACC-M12MSS-3PECT-CM SH | Core Count:3PE; Coding:CT; Feature:SH shielded + CM locking; Type:Signal-power hybrid | 3PE shielded hybrid power/signal connector | 3PE power + control signal for high-interference actuators (e.g., inverter-proximal 3PE motor power) |
| 1404641 | SACC-M12MSS-3PECON-PG11-M | Core Count:3PE; Gland:PG11; Gender:Male | 3PE M12 power connector for PG11 cables | General 3PE M12 power distribution (e.g., 3PE sensor power supply in workshop) |
| 1107268 | SACC-M12MSS-3PECON-PG 9-M | Core Count:3PE; Gland:PG9; Gender:Male | 3PE M12 power connector for PG9 small cables | 3PE power for compact M12 devices (e.g., laboratory 3PE instrument power wiring) |
| 1419639 | SACC-M12MSS-2PECON-PG 9-M | Core Count:2PE; Gland:PG9; Gender:Male | 2PE M12 power connector for PG9 cables | 2PE power supply for low-power M12 sensors (e.g., 2PE proximity sensor power in conveyor systems) |
4.3 MSL Series (4-Core M12 Fiber Connectors)
4-core M12 fiber (FEPL) connectors for optical signal transmission in high-interference environments.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1080235 | SACC-M12MSL-4FEPL-CL SH | Core Count:4; Type:FEPL fiber; Feature:SH shielded + CL locking | 4-core shielded M12 fiber connector | 4-channel fiber signal transmission in high-interference areas (e.g., inverter room 4-group fiber sensor data) |
| 1151368 | SACC-M12MSL-4FEPL-CL | Core Count:4; Type:FEPL fiber; Feature:CL locking | 4-core M12 fiber connector (non-shielded) | 4-channel fiber signal in low-interference cabinets (e.g., control cabinet internal fiber module wiring) |
4.4 MSD Series (4-Core M12 Signal/Power/Control Connectors)
4-core M12 connectors for general signal (Q), power (PL), control (CT), and cable gland (CON) applications, with rich coding and shielding options.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1411068 | SACC-M12MSD-4QO SH PN | Core Count:4; Coding:QO; Feature:SH shielded + PN; Protocol:Signal | 4-core shielded PN-coded signal connector | 4-channel PROFINET PN sensor signal (e.g., chemical plant 4-group pressure sensor data) |
| 1411066 | SACC-M12MSD-4QO SH ETH | Core Count:4; Coding:QO; Feature:SH shielded + ETH; Protocol:Ethernet | 4-core shielded industrial ethernet connector | 4-channel M12 ethernet device connection (e.g., workshop 4-group HMI ETH wiring) |
| 1404401 | SACC-M12MSD-4Q SH PN WL | Core Count:4; Coding:Q; Feature:SH shielded + PN + WL waterproof; Protocol:Signal | 4-core waterproof PN-coded signal connector | Outdoor 4-channel PN sensor signal (e.g., outdoor weather monitoring 4-point sensor data) |
| 1554513 | SACC-M12MSD-4Q SH PN | Core Count:4; Coding:Q; Feature:SH shielded + PN | 4-core PN-coded signal connector | General 4-channel PN sensor wiring (e.g., workshop 4-group temperature sensor signal) |
| 1543223 | SACC-M12MSD-4Q SH | Core Count:4; Coding:Q; Feature:SH shielded | 4-core shielded signal connector | 4-channel shielded sensor signal (e.g., high-interference 4-group proximity sensor data) |
| 1424682 | SACC-M12MSD-4PL SH PN | Core Count:4; Type:PL power; Feature:SH shielded + PN | 4-core PN-coded power connector | 4-channel PN actuator power supply (e.g., 4-group solenoid valve PN power in packaging machines) |
| 1422846 | SACC-M12MSD-4CT-CM SH PN | Core Count:4; Coding:CT; Feature:SH shielded + CM + PN; Type:Control | 4-core PN-coded control signal connector | 4-channel PLC control signal (e.g., robotic arm 4-group end-effector control wiring) |
| 1521261 | SACC-M12MSD-4CON-PG 9-SH | Core Count:4; Gland:PG9; Feature:SH shielded; Type:Cable gland connector | 4-core PG9 shielded cable gland connector | 4-channel PG9 small-cable shielded connection (e.g., cabinet-internal 4-group module wiring) |
| 1521258 | SACC-M12MSD-4CON-PG 7-SH | Core Count:4; Gland:PG7; Feature:SH shielded | 4-core PG7 ultra-small cable shielded connector | 4-channel ultra-small cable signal (e.g., laboratory 4-group precision sensor wiring) |
III. Series Nomenclature Decoding
SACC-[Interface Series]-[Core Count/Type]-[Coding/Function]-[Gland/Feature Suffix]
- SACC: Product series identifier (industrial circular connector for field device interconnection).
- Interface Series:
- MINFR = Compact FR-interface connector (3-5 core, space-constrained);
- M16FR = 14-core M16 FR high-density connector;
- M12 = M12-standard interface (sub-divided into MSX/MST/MSS/MSL/MSD by function);
- MSX = 8-core M12 signal/ethernet;
- MST/MSS = 2PE/3PE M12 power;
- MSL = 4-core M12 fiber (FEPL);
- MSD = 4-core M12 signal/power/control.
- Core Count/Type:
- XCON = X-core general connection (e.g., 5CON=5-core);
- XPE = X-core protective earth power (e.g., 3PE=3-core power);
- XQ/XQO = X-core signal (QO=special coding);
- XPL = X-core power (PL=power contact);
- XCT = X-core control signal (CT=control coding);
- XFEPL = X-core fiber (FEPL=fiber optic).
- Coding/Function:
- QO/CT/PN = System coding (QO=legacy, CT=control, PN=PROFINET power-neutral);
- ETH = Industrial Ethernet compatibility;
- SH = Shielded (EMI protection);
- CL/CM = Locking type (CL=click-lock, CM=mechanical lock);
- WL = Waterproof (enhanced IP protection).
- Gland/Feature Suffix:
- PG7/9/11/13 = Cable gland size (matches cable diameter);
- /2,5 = Supports 2.5mm² high-current cable;
- L 90 = 90° angled accessory;
- M = Male connector (female suffix omitted for standard);
- SET = Complete cable installation kit.
IV. 3-Step Quick Selection Technique
Step 1: Select Series Based on Interface & Space Requirements
- Compact 3-5 core devices (space-constrained): Choose MINFR series (1521478/1521517) for narrow cabinets/mini-devices.
- 14-core high-density hybrid transmission: Opt for M16FR series (1500253) for complex robotic/workstation interconnection.
- M12-standard field devices: Pick M12 functional series (MSX/MSD for signal/ethernet, MST/MSS for power, MSL for fiber).
- M12 installation/deployment: Select M12 basic accessories (SET kit for wiring, SCO NUT for locking).
Step 2: Match Function to Transmission Demand
- Industrial Ethernet/PROFINET: Choose MSX/MSD with ETH/PN suffix (1411043/1411066) for real-time control communication.
- 2PE/3PE power supply: Select MST/MSS series (1404641/1419639) for dedicated PE power transmission.
- Fiber signal (high-interference): Pick MSL series (1080235) with SH shielding for optical data transmission.
- General 4-core signal/power: Opt for MSD series (1543223/1424682) based on coding (Q/PL/CT) needs.
Step 3: Choose Gland/Shielding for Installation Conditions
- Cable diameter matching:
- Ultra-small cables (≤φ7mm): PG7 gland (1521258);
- Small cables (φ7-9mm): PG9 gland (1521261/1107268);
- Medium cables (φ9-11mm): PG11 gland (1404641/1456297);
- Large cables (φ11-13mm): PG13 gland (1456307) (supports 2.5mm² high-current).
- High-interference environments: Select SH shielded variants (1080235/1411044) to suppress EMI.
- Space-constrained installation: Pick 90° angled nuts (1432460) for side-mount device wiring.
V. Recommended Industry-Scenario Combinations
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Automotive Robotics | M12 8-core ETH camera + 4-core PN sensor + 3PE power | 1411043 (MSX-8QO SH ETH) + 1411068 (MSD-4QO SH PN) + 1404641 (MSS-3PECON-PG11-M) |
| Chemical Plant | Outdoor 4-core waterproof PN sensor + 4-core fiber signal + MINFR compact power | 1404401 (MSD-4Q SH PN WL) + 1080235 (MSL-4FEPL-CL SH) + 1521517 (MINFR-5CON-PG9) |
| Packaging Machinery | 4-core PL actuator power + M12 SET wiring kit + 90° angled nut | 1424682 (MSD-4PL SH PN) + 1436505 (M12-SET/2,5-3,5) + 1432460 (M12-SCO NUT L90) |
| Laboratory Precision Control | 4-core PG7 shielded sensor + 3-core MINFR control signal | 1521258 (MSD-4CON-PG7-SH) + 1521478 (MINFR-3CON-PG9) |
VI. Selection Pitfall Avoidance Guide
- Interface Compatibility Error: M12 PLC devices using MINFR connectors → Choose M12 functional series (MSD/MSX) to ensure mechanical/electrical matching and prevent connection failure.
- Shielding Neglect: Inverter-proximal signals using non-SH connectors → Select SH shielded variants (1080235/1411044) to suppress EMI and avoid signal distortion.
- Cable Gland Mismatch: 2.5mm² cables using PG7 glands → Pick PG11/13 glands with /2,5 suffix (1456307/1456297) to ensure cable fixation and IP67 protection.
- Protocol Incompatibility: PROFINET networks using non-PN/ETH connectors → Choose PN/ETH suffix models (1411068/1411043) to enable real-time control communication.
- Space Oversight: Narrow device cavities using straight nuts → Select 90° angled nuts (1432460) to avoid cable bending damage and improve installation fit.
Conclusion: Select the Right SACC Connector for Field Device Interconnection
The Phoenix SACC-MINFR/M16FR/M12 series provides targeted circular connection solutions for compact, high-density, and M12-standard industrial devices, covering signal, power, ethernet, and fiber transmission with diverse coding and shielding options.