Phoenix UT 6-TMC M/ECP/CTM Series Current/Voltage Matching Terminals & Contact Modules Selection Guide

Phoenix this batch of products covers three core series including UT 6-TMC M (6mm² precision current rating terminals), ECP/ECP-E3 (modular current specification terminals), and CTM (multi-contact AC/DC voltage adaptation modules). They feature 0.5A–16A wide current coverage and 12DC–110AC voltage adaptation, with modular DIN rail mounting design, suitable for industrial control circuit current matching, signal contact switching/expansion, and AC/DC voltage adaptive connection scenarios.

1. Core Model Classification & Product Specifications

Classified by product function and structural characteristics, with detailed parameter matching, product codes and application positioning for quick selection:

1.1 UT 6-TMC M Series (6mm² Precision Current Rating Terminals, 0916603-0916613)

6mm² wire gauge dedicated precision current rating terminals, with single fixed current grade (0.5A–16A), clear current marking, modular design, suitable for fixed current matching of 6mm² control/power circuits (one terminal for one current grade, high matching accuracy).

Product Code Model Rated Current Core Features Application Scenarios
0916603 UT 6-TMC M 0,5A 0.5A 6mm², ultra-low current precision matching Micro-signal 6mm² circuit current limiting/matching
0916604 UT 6-TMC M 1A 1A 6mm², small current fixed matching Low-power 6mm² control circuit current matching
0916605 UT 6-TMC M 2A 2A 6mm², small current fixed matching Basic 6mm² signal circuit current matching
0916606 UT 6-TMC M 4A 4A 6mm², medium small current matching 6mm² actuator control circuit current matching
0916607 UT 6-TMC M 5A 5A 6mm², medium small current matching 6mm² sensor power circuit current matching
0916608 UT 6-TMC M 6A 6A 6mm², medium current matching 6mm² low-power power circuit current matching
0916609 UT 6-TMC M 8A 8A 6mm², medium current matching 6mm² industrial control circuit current matching
0916610 UT 6-TMC M 10A 10A 6mm², medium-high current matching 6mm² motor auxiliary circuit current matching
0916611 UT 6-TMC M 12A 12A 6mm², medium-high current matching 6mm² pump/fan control circuit current matching
0916612 UT 6-TMC M 15A 15A 6mm², high current matching 6mm² medium-power power circuit current matching
0916613 UT 6-TMC M 16A 16A 6mm², high current matching 6mm² main control circuit current matching

1.2 ECP/ECP-E3 Series (Modular Current Specification Terminals, 0912018-0912052/0916536)

Divided into ECP-E3 enhanced type (1A–12A single current grade) and ECP basic type (current segment matching: 1-2A/3-6A/10A), small-size modular design, suitable for small wire gauge control circuit current segment matching (cost-effective, wide current coverage for one module).

1.2.1 ECP-E3 Enhanced Type (Single Current Grade, 0912041-0912052)

Product Code Model Rated Current Core Features Application Scenarios
0912041 ECP-E3 1A 1A Enhanced contact, small current precision matching Micro-signal control circuit current matching
0912042 ECP-E3 2A 2A Enhanced contact, small current fixed matching Basic sensor signal circuit current matching
0912043 ECP-E3 3A 3A Enhanced contact, medium small current matching Actuator low-power control circuit current matching
0912044 ECP-E3 4A 4A Enhanced contact, medium small current matching Solenoid valve control circuit current matching
0912046 ECP-E3 6A 6A Enhanced contact, medium current matching Low-power motor auxiliary circuit current matching
0912048 ECP-E3 8A 8A Enhanced contact, medium current matching Industrial control panel circuit current matching
0912050 ECP-E3 10A 10A Enhanced contact, medium-high current matching Pump/fan auxiliary control circuit current matching
0912052 ECP-E3 12A 12A Enhanced contact, medium-high current matching Medium-power control circuit current matching

1.2.2 ECP Basic Type (Current Segment Matching, 0912018/0916536/0912020)

Product Code Model Current Matching Segment Core Features Application Scenarios
0912018 ECP 1-2 1A–2A Cost-effective, small current segment coverage General micro-signal circuit current matching
0916536 ECP 3-6 3A–6A Cost-effective, medium small current segment coverage General actuator/sensor control circuit current matching
0912020 ECP 10 10A Cost-effective, medium-high current fixed matching General low-power power circuit current matching

1.3 CTM Series (Multi-contact AC/DC Voltage Adaptation Modules, 2838500-2838610)

Small-size contact modules with two contact configurations (2X1/1X2), supporting 12DC–110AC wide voltage adaptation (DC 12/24/60V, AC 110V), suitable for signal circuit contact switching/expansion, AC/DC voltage adaptive signal transmission (one module for multi-path contact, compact structure).

Product Code Model Contact Configuration Rated Voltage Core Features Application Scenarios
2838500 CTM 2X1- 24DC 2 groups × 1 channel DC 24V Dual-group single-path, DC 24V mainstream signal 24V DC sensor signal circuit contact expansion
2838542 CTM 2X1- 60DC 2 groups × 1 channel DC 60V Dual-group single-path, medium DC voltage 60V DC actuator signal circuit contact switching
2838526 CTM 2X1-110AC 2 groups × 1 channel AC 110V Dual-group single-path, AC 110V industrial voltage 110V AC control circuit contact expansion
2838597 CTM 1X2- 12DC 1 group × 2 channels DC 12V Single-group dual-path, low DC voltage 12V DC small equipment signal circuit contact shunt
2838513 CTM 1X2- 24DC 1 group × 2 channels DC 24V Single-group dual-path, DC 24V mainstream signal 24V DC signal one-to-two contact shunt/transmission
2838539 CTM 1X2-110AC 1 group × 2 channels AC 110V Single-group dual-path, AC 110V industrial voltage 110V AC control signal one-to-two contact shunt
2838610 CTM 10-MAG - - MAG magnetic structure, 10-spec Magnetic control type signal circuit contact connection

2. Quick Interpretation of Model Naming Rules

The naming logic of the three series follows Phoenix's standardized industrial terminal/module specification, with each segment corresponding to clear wire gauge, current/voltage, structure/configuration parameters:

Series Naming Segment Meaning & Explanation
UT 6-TMC M UT Phoenix universal terminal core series
  6 Compatible wire gauge: 6mm² (fixed for this series)
  TMC Special structural type of terminal (modular current rating design)
  M Mounting/interface type: DIN rail modular mounting (adapt to standard NS35/32 rail)
  XA Rated current grade (0.5A–16A, single fixed current for one model)
ECP/ECP-E3 ECP Current specification terminal core series (modular current matching)
  E3 Enhanced type (3rd generation enhanced contact, higher stability than basic ECP)
  XA/X-X Rated current: XA=single current grade (1A–12A for ECP-E3); X-X=current matching segment (1-2A/3-6A for basic ECP)
CTM CTM Contact module core series (AC/DC voltage adaptation, contact switching/expansion)
  X×Y Contact configuration: X=group number, Y=channel number per group (2X1=2 groups 1 channel; 1X2=1 group 2 channels)
  XXV(DC/AC) Rated voltage: XX=voltage value, DC/AC=power type (12DC/24DC/60DC/110AC)
  10-MAG 10=product spec; MAG=magnetic control structure (special contact drive mode)

3. Core Advantages of This Batch of Products

3.1 UT 6-TMC M Series

  1. 6mm² fixed wire gauge + precision current rating: 0.5A–16A full current coverage, one terminal for one current grade, high matching accuracy for 6mm² circuit.
  2. Modular DIN rail mounting: Adapt to standard NS35/32 rail, consistent with Phoenix other terminal series, standardized cabinet wiring.
  3. Clear current marking: Integral current grade marking, no additional labeling, reducing maintenance errors in complex circuits.

3.2 ECP/ECP-E3 Series

  1. Two-tier product positioning: ECP-E3 enhanced type with high-stability contact for precision current matching; ECP basic type with current segment coverage for cost-sensitive scenarios.
  2. Small-size modular design: Compact structure, saves cabinet installation space, suitable for small wire gauge control circuit dense wiring.
  3. Wide current coverage: 1A–12A full coverage for ECP-E3; 1-2A/3-6A/10A segment coverage for ECP, meeting most small current control circuit needs.

3.3 CTM Series

  1. Dual contact configuration + wide voltage adaptation: 2X1 (expansion) /1X2 (shunt) two configurations, 12DC–110AC AC/DC voltage coverage, one module for multiple signal circuit needs.
  2. Miniaturized design: Ultra-small form factor, suitable for narrow-space equipment internal signal circuit wiring.
  3. Diverse application modes: Support contact switching, signal expansion, one-to-two shunt, adapt to different signal transmission topologies.

4. Product Selection Suggestions

4.1 Select by Current Matching Requirement & Wire Gauge

  1. 6mm² wire gauge circuit (0.5A–16A): Prioritize UT 6-TMC M series (precision single current grade, high matching accuracy, e.g., 0916605 UT 6-TMC M 2A for 2A 6mm² signal circuit).
  2. Small wire gauge control circuit (1A–12A): Choose ECP/ECP-E3 series (ECP-E3 enhanced type for high stability needs, e.g., 0912042 ECP-E3 2A; ECP basic type for cost-sensitive, e.g., 0912018 ECP 1-2 for 1-2A segment).
  3. No wire gauge limit, focus on contact switching/voltage adaptation: Select CTM series (match by contact configuration and voltage, e.g., 2838513 CTM 1X2-24DC for 24V DC one-to-two signal shunt).

4.2 Select by Functional Requirement (Current/Signal)

  1. Pure current matching/fixed (no contact switching): Choose UT 6-TMC M or ECP/ECP-E3 (current-oriented terminals, high current stability).
  2. Signal contact switching/expansion/shunt (with voltage adaptation): Must select CTM series (contact-oriented module, support AC/DC voltage and multi-path contact).

4.3 Select by CTM Contact Configuration & Voltage

  1. Signal circuit expansion (one signal to two independent circuits): Choose 2X1 configuration (2 groups 1 channel, independent expansion, e.g., 2838500 CTM 2X1-24DC).
  2. Signal circuit one-to-two shunt (one signal to two parallel circuits): Choose 1X2 configuration (1 group 2 channels, parallel shunt, e.g., 2838513 CTM 1X2-24DC).
  3. DC signal (12/24/60V): Select DC voltage models (e.g., 12DC for small equipment, 24DC for industrial mainstream, 60DC for medium DC voltage).
  4. AC signal (110V): Select 110AC models (e.g., 2838526 CTM 2X1-110AC, 2838539 CTM 1X2-110AC).

4.4 Select by Cost & Stability Requirement

  1. High stability/precision matching (industrial control core circuit): Choose UT 6-TMC M (6mm²) or ECP-E3 (small current) (enhanced structure, low failure rate).
  2. Cost-sensitive/general circuit (non-core signal/control): Choose ECP basic type (current segment) (one module covers multiple current grades, low cost).

Phoenix UT 6-TMC M/ECP/CTM Series Current/Voltage Matching Terminals & Contact Modules Selection Guide

Created on:2026-01-30 09:57

News Dynamics

NEWS