Phoenix MACX MCR-T-UIREL-UP-SP-temperature measurement transmitter 2811828, freely programmable temperature measurement transmitter, with analog output and 3 threshold relays, standard configuration, 2-, 3-or 4-wire resistance thermometer, thermocouple, galvanic isolation, wide-area power supply, plug-in interface, SIL,PL.
Product Type |
temperature measurement transmitter |
product series |
MACX Analog |
Model |
isolation amplifier with SIL and PL functional safety |
configuration |
DIP switch |
Software |
insulation characteristics |
Overvoltage Category |
II |
pollution level |
2 |
electrical isolation |
4 road isolation |
step response (0-99%) |
≤ 1.75 s (SIL on) |
1.3 s (SIL off) |
maximum temperature coefficient |
0.01 %/K |
Maximum transmission error |
0.1 % (e. g. for Pt 100,300 K range, 4 ... 20 mA) |
Electrical isolation input/output/power supply |
Rated insulation voltage |
300Vrms |
Test Voltage |
2.5 kV AC (50 Hz, 60 s) |
insulation |
safety isolation conforming to IEC/EN 61010-1 |
electrically isolated input/output |
electrical isolation |
375V (peak according to IEC/EN 60079-11) |
Electrically isolated input/power supply |
electrical isolation |
375V (peak according to IEC/EN 60079-11) |
galvanically isolated input/switch output |
electrical isolation |
375V (peak according to IEC/EN 60079-11) |
Power |
Rated supply voltage range |
24V AC/DC ... 230V AC/DC -20 % ... +10 % (50/60 Hz) |
Supply Voltage Range |
19.2V AC/DC ... 253V AC/DC (50/60 Hz) |
Typical current consumption |
< 100 mA (24V DC) |
power consumption |
< 2.4W |
signal |
Input Number |
1 |
input signal |
temperature |
resistance |
voltage |
measurement |
Available Sensor Types (RTDs) |
Pt, Ni, Cu sensors: 2, 3, 4 wires |
Available Sensor Types (TC) |
B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG |
Temperature measurement range |
-250°C ... 2500°C (range depends on sensor type) |
Linear resistance measuring range |
0 Ω ... 50 kΩ |
potentiometer, resistance range |
0 Ω ... 50 kΩ |
Linear mV Signal Range |
-1000 mV ... 1000 mV |
switching: relay |
configurable/programmable |
is |
Contact Type |
3 changeover contacts |
Contact Material |
AgSnO2, hard gold plated |
maximum switching voltage |
250V AC (250V DC) |
maximum switching current |
2 A (250V AC) |
0.1 A (250V DC) |
2 A (28V DC) |
signal: current/voltage |
outputs |
1 |
configurable/programmable |
is |
Maximum voltage output signal |
± 11V |
current output signal |
4 mA ... 20 mA (in SIL; more configuration without SIL) |
Maximum current output signal |
22 mA |
load/output load voltage output |
≥ 10 kΩ |
load/output load current output |
≤ 600 Ω (20 mA) |
sensor fails |
can be freely programmed |
Connection Mode |
in-line connection |
stripping length |
10mm |
Rigid conductor cross section |
0.2 mm² ... 2.5 mm² |
Flexible Wire Cross Section |
0.2 mm² ... 2.5 mm² |
flexible wire cross section (2 wires with the same cross section) |
0.25 mm² ... 0.34 mm² (TWIN cold press head without plastic sleeve) |
0.5 mm² ... 1.5 mm² (TWIN sleeve with plastic insulating sleeve) |
Attachable Guide Cross Section AWG |
24 ... 14 |
24 ... 22 (TWIN cold head without plastic sleeve) |
20 ... 16 (TWIN sleeve with plastic insulation sleeve) |