Phoenix MINI MCR-2-IDS-I-I-PT-output isolation amplifier 2905625, output signal isolation transmitter, used to isolate 0 mA / 4 mA ... 20 mA signals and transmit them from the controller to the intraparty load in the potential explosion zone. HART transparent, no-load voltage: 27V DC, standard configuration, in-line connection

Phoenix MINI MCR-2-IDS-I-I-PT-output isolation amplifier 2905625, output signal isolation transmitter, used to isolate 0 mA / 4 mA ... 20 mA signals and transmit them from the controller to the intraparty load in the potential explosion zone. HART transparent, no-load voltage: 27V DC, standard configuration, in-line connection

Product Type Output Isolation Amplifier
product series MINI Analog Pro
configuration DIP switch

Function
configuration DIP switch

signal transmission behavior In = Out
maximum temperature coefficient 0.01 percent
Maximum transmission error 0.1 percent
electrical isolation
Overvoltage Category II (≤ 5000 m)
pollution level 2 (≤ 5000 m)
Electrically isolated input/output/power supply IEC/EN 61010-1
Standards/Regulations IEC/EN 61010-1
Rated insulation voltage 300Vrms
Test Voltage 2.5 kV AC (50 Hz, 60 s)
insulation Double/reinforced insulation
galvanically isolated input/output/power supply IEC/EN 60079-7
Standards/Regulations IEC/EN 60079-7
Rated insulation voltage 251Vrms
power supply
Rated supply voltage 24V DC
Supply Voltage Range 19.2V DC ... 30V DC
power consumption ≤ 1.2W

signals: current
Input Number 1
current input signal 0 mA ... 20 mA
4 mA ... 20 mA
input current ≤ 30 mA
voltage drop < 3.5V DC (20 mA)

signals: current
outputs 1
current output signal 0 mA ... 20 mA
4 mA ... 20 mA
load/output load current output ≤ 700 Ω (20 mA)
≤ 630 Ω (21 mA)
output fluctuation 20 mV (rms)
No-load voltage ≤ 27V DC
Short-circuit protection is
Line Fault Detection > 10 k Ω (line break)
< 50 Ω (short circuit)

Connection Mode in-line connection
stripping length 10mm
Rigid conductor cross section 0.2 mm² ... 1.5 mm² (with cold press head)
0.14 mm² ... 2.5 mm² (without cold head)
Flexible Wire Cross Section 0.14 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 12 (flexible)

Function
configuration DIP switch

signal transmission behavior In = Out
maximum temperature coefficient 0.01 percent
Maximum transmission error 0.1 percent
electrical isolation
Overvoltage Category II (≤ 5000 m)
pollution level 2 (≤ 5000 m)
Electrically isolated input/output/power supply IEC/EN 61010-1
Standards/Regulations IEC/EN 61010-1
Rated insulation voltage 300Vrms
Test Voltage 2.5 kV AC (50 Hz, 60 s)
insulation Double/reinforced insulation
galvanically isolated input/output/power supply IEC/EN 60079-7
Standards/Regulations IEC/EN 60079-7
Rated insulation voltage 251Vrms
power supply
Rated supply voltage 24V DC
Supply Voltage Range 19.2V DC ... 30V DC
power consumption ≤ 1.2W

signals: current
Input Number 1
current input signal 0 mA ... 20 mA
4 mA ... 20 mA
input current ≤ 30 mA
voltage drop < 3.5V DC (20 mA)

signals: current
outputs 1
current output signal 0 mA ... 20 mA
4 mA ... 20 mA
load/output load current output ≤ 700 Ω (20 mA)
≤ 630 Ω (21 mA)
output fluctuation 20 mV (rms)
No-load voltage ≤ 27V DC
Short-circuit protection is
Line Fault Detection > 10 k Ω (line break)
< 50 Ω (short circuit)

Connection Mode in-line connection
stripping length 10mm
Rigid conductor cross section 0.2 mm² ... 1.5 mm² (with cold press head)
0.14 mm² ... 2.5 mm² (without cold head)
Flexible Wire Cross Section 0.14 mm² ... 2.5 mm²
Connectable Guide Cross Section AWG 24 ... 12 (flexible)
2902040