| Cable Length |
5 m |
| gray, highly flexible PUR [800] |
| Dimensional drawing |
|
| Considerations |
the outer sheath of this cable is extremely strong, it can only be stripped in 5cm increments. |
| Cable Weight |
33.5 kg/km |
| UL AWM |
20549 |
| Bits |
4 |
| Shielding |
None |
| Cable Type |
gray, highly flexible PUR [800] |
| wire structure signal line |
42x 0.10mm |
| AWG, signal wire |
22 |
| Wire Cross Section |
4x 0.34 mm² (signal line) |
| wire diameter, including insulation |
1.3mm ± 0.05mm (signal line) |
| Cable outer diameter |
4.80mm ± 0.2mm |
| outer sheath, material |
PUR |
| outer sheath, color |
gray RAL 7001 |
| Wire Material |
copper stranded wire |
| wire insulation material |
PP |
| single line, color |
Brown, white, blue, black |
| Total Strand |
4 wire, stranded |
| Maximum conductor resistance |
approx. 53 Ω/km |
| insulation resistance |
≥ 20 MΩ*km |
| Rated voltage, cable |
300V |
| Test Voltage |
2000V |
| minimum bending radius, fixed installation |
4 x D |
| minimum bending radius, movable installation |
7,5 x D |
| minimum bending radius, fixed mounting |
20mm |
| minimum bending radius, mobile installation |
36mm |
| Dynamic Load Capacity (Bending) |
Maximum bending times: 1000000, bending radius: 7,5 x D, lateral trajectory: 5 m, lateral speed: 3.3 m/s, acceleration: 5 m/s |
| Maximum bending times: 150000, Bending radius: 50mm, Transverse trajectory: 0.9 m, Transverse speed: 5 m/s, Acceleration: 30 m/s |
| dynamic load capacity (torsional) |
torque: ± 360 °/m, torsion cycle: 1000000, torsion frequency: 35 times/min |
| Halogen-free |
according to DIN VDE 0472 Chapter 815 |
| flame retardant |
Complies with UL 758/1581 FT2 |
| oil resistance |
according to DIN EN 60811-2-1 |
| Other protective functions |
good resistance to acid, alkali solution and solvent |
| does not contain silicone |
| special nature |
cable sheath welding is spark resistant, recyclable, matt, low adhesion, abrasion resistant, flame retardant, and self-extinguishing |
| is free of silicon and cadmium |
| without substances affecting the paint coating |
| ambient temperature (operation) |
-40°C ... 80°C (cable, fixed installation) |
| -25°C ... 80°C (cable, movable installation) |