Phoenix RCK-TGUM/BL12/20,0PUR-U-main cable 1514469, main cable, number of digits: 12, status display: no; Main cable connection: M23 hole connector, cable length: 20 m, shielding: none, according to RoHS II directive (excluding exemption clause 6c, I .e. lead content <0.1), this product is expected to be lead-free from the fourth quarter of 2025; If you need to obtain lead-free alternatives in advance, you can

Product Type main cable, prefabricated
Bits 12

Rated voltage UN 48V AC
60V DC

Connection Mode fixed connection

Status Display No

Identification Material Shell PUR
contact material, main cable end copper alloy
Main cable side contact ferrule material PA
contact surface material, main cable end gold-plated

Cable Length 20 m
PUR/PVC Black [PUR]
Dimensional drawing
Cable Weight 107.4 kg/km
UL AWM 20549 (80°C/300 V)
Bits 11
Shielding None
Cable Type PUR/PVC Black [PUR]
wire structure signal line 19x 0.15mm
AWG, signal wire 22
wire structure, voltage power supply 42x 0.15mm
AWG Power Supply 18
Wire Cross Section 8x 0.34 mm² (signal line)
3x 0.75 mm² (power cord)
wire diameter, including insulation 1.3mm ± 0.1mm (signal line)
1.8mm ± 0.1mm (power cord)
Cable outer diameter 8.50mm ± 0.2mm
outer sheath, material PUR
outer sheath, color Black RAL 9005
Wire Material copper stranded wire
wire insulation material PVC
single line, color Brown, Blue, Green/Yellow, White, Green, Yellow, Gray, Pink, Red, Black, Purple
inner sheath thickness ≥ 0.15mm
thickness, outer sheath ≥ 0.38mm
Total Strand Twisted Pair
Maximum conductor resistance ≤ 53 Ω/km (signal line)
≤ 26 Ω/km (power line)
insulation resistance ≥ 5 MΩ*km
Rated voltage, cable 300V AC
Core test voltage/core 2000V (50 Hz,5 min)
minimum bending radius, fixed installation 7,5 x D
minimum bending radius, movable installation 10 x D
minimum bending radius, fixed mounting 64mm
minimum bending radius, mobile installation 85mm
Dynamic Load Capacity (Bending) Maximum bending times: 1500000, Bending radius: 10 x D, Transverse trajectory: 2 m, Transverse speed: 2 m/s
flame retardant DIN EN 50265
oil resistance Complies with VDE 0472 part 803
Other protective functions good resistance to acid, alkali solution and solvent
special nature does not contain silicone
ambient temperature (operation) -40°C ... 90°C (cable, fixed installation)
-5°C ... 80°C (cable, movable installation)

environmental conditions
protection level IP65
IP67
ambient temperature (operation) -40°C ... 125°C
1684069

Phoenix RCK-TGUM/BL12/20,0PUR-U-Main cable 1514469

Product Center