Phoenix MINI MCR-2-RPSS-I-I-PT-feed isolator 2902015,3-end feed isolator, using plug-in connection technology. HART transparent, input signal 0(4) mA ... 20 mA, output signal 0(4) mA ... 20 mA. The device can be used in isolator and feeder isolator operations. In-line connection technology
Use Restrictions
EMC Description
EMC: Class A products, see the manufacturer's declaration in the download area
Product Type
Feeder Isolator
Product Series
MINI Analog Pro
Channels
1
Model
isolation amplifier
insulation characteristics: GB Standard
Overvoltage Category
II
pollution level
2
electrical isolation
3 End Isolation
galvanic isolation between input and output
is
cut-off frequency (3dB)
> 1.75 kHz
protection circuit
transient protection
Signal Transmission Behavior
In = Out
step response (10-90%)
< 200 & micro;s (typical)
maximum temperature coefficient
0.0075 %/K
temperature coefficient, typical
0.0075 %/K
Maximum transmission error
0.05 % (final value in repeater power supply operation)
0.1 % (final value in isolator operation)
Electrical isolation input/output/power supply
Rated insulation voltage
300Vrms
Test Voltage
3 kV AC (50 Hz, 60 s)
insulation
reinforced insulation conforming to IEC/EN 61010-1
Power
Rated supply voltage
24V DC
Supply Voltage Range
9.6V DC ... 30V DC (DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, order number 2869728) can be used to bridge the power supply. Can be stuck to a 35mm DIN rail conforming to the EN60715 standard))
Typical current consumption
25 mA (24VDC, isolator operation)
50 mA (24VDC, feeder isolator operation)
55 mA (12VDC, isolator operation)
110 mA (12VDC, feeder isolator operation)
power consumption
≤ 1400 mW (IOUT= 20 mA,9.6V DC,600 Ω load)
signals: current
Input Description
sensor circuit
Input Number
1
current input signal
0 mA ... 20 mA (Isolator operation)
4 mA ... 20 mA (feeder isolator and isolator operation)
input current
(+0.7V for testing diodes)
Transmitter supply voltage
> 19.5V
signals: current
outputs
1
No-load voltage
< 20V
current output signal
0 mA ... 20 mA (Isolator operation)
4 mA ... 20 mA (feeder isolator and isolator operation)
Maximum current output signal
24 mA
load/output load current output
≤ 600 Ω (20 mA)
fluctuation
< 20 mVSS(600 Ω)
Connection Mode
in-line connection
stripping length
10mm
Rigid conductor cross section
0.2 mm² ... 2.5 mm² (with cold press head)
0.14 mm² ... 2.5 mm² (without cold head)
Flexible Wire Cross Section
0.14 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG
24 ... 12 (flexible)
Explosion-proof installation (EPL)
Gc
Div. 2
Data Communication (Bypass)
HART function
is
cut-off frequency (3dB)
1.75 kHz
2902040