Phoenix ELR H5-ES-SC- 24DC/500AC-2-hybrid motor starter 2900559, hybrid motor starter, used for reverse starting three-phase AC motors, up to 550V AC,24V DC input, 2.4 A output current, Emergency stop function.

Product Type hybrid motor starter
product series CONTACTRON
Mode of operation 100% operating factor

phase number 3
Motor Starter Type reversible starter
Switching frequency ≤ 2Hz (depending on load)
rated conditions 2.2W
Switching frequency ≤ 2Hz (depending on load)
Maximum power loss 3.3W
minimum power loss 1.1W
type of coordination 1
power supply
Rated control circuit supply voltage US 24V DC
Control Supply Voltage Range 19.2V DC ... 30V DC
Rated control supply current IS 40 mA
protection circuit Surge Protection
polarity protection
insulation characteristics
Rated insulation voltage 500V
Rated overvoltage 6 kV
Overvoltage Level III
pollution level 2
control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit safety insulation (IEC 60947-1/EN 50178) for operating voltages ≤ 300V AC
operating voltage 300V AC ... 500V AC (IEC 60947-1)
safety insulation (EN 50178), suitable for working voltage 300 ... 500V AC
control input and control supply voltage to auxiliary circuits safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits
safety insulation (EN 50178), in auxiliary circuits ≤ 300V AC

control
Enter Name Control Input Right/Left
Rated operating voltage UC 24V DC
Trigger voltage range 19.2V DC ... 30V DC
Rated operating current IC 5 mA
Switch Threshold 9.6V ("0" signal)
19.2V ("1" signal)
switch level < 5V DC (for emergency stop)
Typical closing time < 30 ms
protection circuit polarity protection

AC output
Rated operating voltage Ue 500V AC
Operating voltage range 42V AC ... 550V AC
Rated operating current Ie 2.4 A (AC-51)
2.4 A (AC-53a)
mains frequency 50/60Hz
Load current range 180 mA ... 2.4 A (see attenuation curve)
action characteristics according to IEC 60947-4-2 Class 10A
cooling time 20 min (for automatic reset)
leakage current 0 mA
protection circuit Surge Protection
Confirm Output
Considerations confirmation: floating transfer contact, signal contact
Contact Type 1 changeover contact
switching capacity according to IEC 60947-5-1 3 A (230 V, AC15)
2 A (24V (DC13))
2900559

Phoenix ELR H5-ES-SC- 24DC/500AC-2-Hybrid Motor Starter 2900559

Product Center