Phoenix MACX MCR-EX-SL-2NAM-R-UP-isolation amplifier 2865984,2-channel Ex-i NAMUR isolation amplifier, with safe electrical isolation and wide-area power supply, used for proximity switches and switches. Each channel has a relay with PDT contacts as the signal output. Line fault detection (LFD),3-terminal isolation, SIL 2.

Product Type isolation amplifier
Product Series MACX Analog
Channels 2
Model Ex I Isolation Amplifier with SIL Functional Safety
configuration DIP switch

Function
configuration DIP switch

electrical isolation 3 End Isolation
galvanic isolation between input and output is
rated conditions ≤ 1.3W
step response (10-90%) Typical 6 ms (N/O contact: OFF/ON)
Typical 6 ms (N/O contact: ON/OFF)
Typical 4 ms (N/C contact: ON/OFF)
Typical 10 ms (N/C contact: OFF/ON)
electrical isolation
Test Voltage 2.5 kV AC (50 Hz, 60 s)
electrical isolation input/output IEC/EN 60079-11
Standards/Regulations IEC/EN 60079-11
Rated insulation voltage 375VPP
Overvoltage Category III
pollution level 2
galvanically isolated input/power supply IEC/EN 60079-11
Standards/Regulations IEC/EN 60079-11
Rated insulation voltage 375VPP
Overvoltage Category II
pollution level 2
electrically isolated input/power supply IEC/EN 61010-1
Standards/Regulations IEC/EN 61010-1
Rated insulation voltage 300Vrms
Overvoltage Category II
pollution level 2
insulation security isolation
galvanically isolated output 1/output 2/input, power supply IEC/EN 61010-1
Standards/Regulations IEC/EN 61010-1
Rated insulation voltage 300Vrms
Overvoltage Category III
pollution level 2
insulation security isolation
Power
Rated supply voltage range 24V AC/DC ... 230V AC/DC -20 % ... +10 % (50/60 Hz)
Supply Voltage Range 19.2V AC/DC ... 253V AC/DC (50/60 Hz)
Maximum current consumption < 80 mA
< 42 mA (24V DC)
power consumption < 1.1W
power consumption < 1.1W

signal: NAMUR
Input Description intrinsic safety
Input Number 2
valid input source NAMUR proximity switch sensor (IEC/EN 60947-5-6)
Floating switch contact
Switch contacts with resistor circuit
switch threshold "0" signal current < 1.2 mA (disabled)
switch threshold "1" signal, current > 2.1 mA (ON)
short-circuit current 8 mA
switching hysteresis < 0.2 mA
Line Fault Detection < 0.05 mA ... 0.35 mA (line break)
< 100 Ω ... 360 Ω (short circuit)
activated/deactivated via DIP switch
No-load voltage 8V DC