Phoenix MINI MCR-2-TC-UI-thermocouple measurement transmitter 2902055, a configurable temperature transmitter with plug-in connection technology, used to connect thermocouples. Configuration via DIP switch or software. Screw connection technology, standard configuration
Product Type
temperature measurement transmitter
Product Series
MINI Analog Pro
Model
isolation amplifier
configuration
DIP switch
Software
Application
insulation characteristics
Overvoltage Category
II
pollution level
2
electrical isolation
3 End Isolation
Typical Cold Point Error
2 K (2 K +(0.2 K * ΔT))
protection circuit
transient protection
step response (0-99%)
300 ms
570 ms
maximum temperature coefficient
≤ 0.01 %/K
transmission fault thermocouple signal
0.1% * 600 K/set measuring range; 0.1% > 600 K(C, E, J, K, N, T, L, U, M Gost, L Gost)
reinforced insulation conforming to IEC/EN 61010-1
power supply
Supply Voltage Range
9.6V DC ... 30V DC (DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, order number 2869728) can be used to bridge the power supply. Can be stuck to a 35mm DIN rail conforming to the EN60715 standard))
Typical current consumption
32.7 mA (24V DC)
66.8 mA (12V DC)
power consumption
≤ 850 mW (IOUT= 20 mA,9.6V DC,600 Ω load)
signal
Input Number
1
measurement
Input Number
1
configurable/programmable
is
Input Voltage Range
- 500 mV ... 500 mV (can be set via software)
Available Sensor Types (TC)
B, C, E, J, K, N, R, S, T, L, U, A- 1, A- 2, A- 3, M, L
Temperature measurement range
-250°C ... 2500°C (range depends on the sensor type and can be set freely via software or incrementally from -150°C to 1350°C via DIP switch)
Temperature measurement range
≥ 50 K
Voltage Range
3 mV
2902040
넳넲