Phoenix MINI MCR-2-TC-UI-PT-thermocouple measurement transmitter 2905249, a configurable temperature transmitter with plug-in connection technology, used to connect thermocouples. Configuration via DIP switch or software. Plug-in connection technology, standard configuration
Product Type
temperature measurement transmitter
Product Series
MINI Analog Pro
Model
isolation amplifier
configuration
DIP switch
Software
Application
insulation characteristics
Overvoltage Category
II
pollution level
2
Function
configuration
DIP switch
Software
Application
electrical isolation
3 End Isolation
Typical Cold Point Error
2 K (2 K +(0.2 K * ΔT))
protection circuit
transient protection
step response (0-99%)
300 ms
570 ms
maximum temperature coefficient
≤ 0.01 %/K
transmission fault thermocouple signal
0.1% * 600 K/set measuring range; 0.1% > 600 K(C, E, J, K, N, T, L, U, M Gost, L Gost)
reinforced insulation conforming to IEC/EN 61010-1
Power
Supply Voltage Range
9.6V DC ... 30V DC (DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, order number 2869728) can be used to bridge the power supply. Can be clamped to a 35mm DIN rail conforming to the EN60715 standard))
Typical current consumption
32.7 mA (24V DC)
66.8 mA (12V DC)
power consumption
≤ 850 mW (IOUT= 20 mA,9.6V DC,600 Ω load)
signal
Input Number
1
measurement
Input Number
1
configurable/programmable
is
Input Voltage Range
- 500 mV ... 500 mV (can be set via software)
Available Sensor Types (TC)
B, C, E, J, K, N, R, S, T, L, U, A- 1, A- 2, A- 3, M, L