Phoenix SAC-4P- 5,0-PVC/M12FR-sensor/actuator cable 1693539, sensor/actuator cable, 4-position, PVC, black RAL 9005, free outlet, with hole elbow M12, code: A, cable length: 5 m
| Product Type |
Sensor/Actuator Cable |
| Application |
standard |
| Bits |
4 |
| Outlet No. |
1 |
| Shielding |
None |
| coding |
A |
| insulation characteristics |
| Overvoltage Category |
II |
| pollution level |
3 |
| flame retardant rating to UL 94 |
HB |
| sealing material |
NBR |
| Fixture body material |
TPU, high flame retardancy, with self-extinguishing properties |
| Contact Material |
CuSn |
| Material Contact Surface |
Ni/Au |
| Contact Carrier Material |
TPU GF |
| screw connection material |
zinc cast, nickel plated |
| insulation resistance |
≥ 10 MΩ |
| Rated voltage UN |
250V AC |
| 250V DC |
| Rated current IN |
4 A |
| Mechanical parameters |
| Insertion/unplugging cycle |
≥ 100 |
| Status Display |
None |
| Status Display |
No |
| Wire Connection |
| Tightening torque |
0.4 Nm |
| connection 1 |
| type |
Free Outlet |
| Connection 2 |
| type |
Hole Elbow M12 |
| Bits |
4 |
| Error-proofing code type |
A |
| Cable Length |
5 m |
| PVC black [PVC] |
| Dimensional drawing |
|
| Cable Weight |
40 kg/km |
| UL AWM |
2464 / 1729 (80°C/300 V) |
| Bits |
4 |
| Shielding |
None |
| Cable Type |
PVC black [PVC] |
| wire structure signal line |
19x 0.15mm |
| AWG, signal wire |
22 |
| Wire Cross Section |
4x 0.34 mm² (signal line) |
| wire diameter, including insulation |
1.26mm ± 0.05mm |
| Cable outer diameter |
4.70mm ± 0.15mm |
| outer sheath, material |
PVC |
| outer sheath, color |
Black RAL 9005 |
| Wire Material |
copper stranded wire |
| wire insulation material |
PVC |
| single line, color |
Brown, white, blue, black |
| thickness, insulation |
≥ 0.23mm (core insulation) |
| thickness, outer sheath |
≥ 0.76mm |
| Total Strand |
4 wire, stranded |
| Maximum conductor resistance |
≤ 57 Ω/km (at 20°C) |
| insulation resistance |
≥ 200 MΩ * km (at 20°C) |
| Rated voltage, cable |
≤ 300V |
| Test Voltage |
≥ 3000V |
| minimum bending radius, fixed installation |
5 x D |
| minimum bending radius, movable installation |
10 x D |
| minimum bending radius, fixed mounting |
24mm |
| minimum bending radius, mobile installation |
47mm |
| flame retardant |
Complies with UL 2464 standards |
| oil resistance |
according to DIN EN 60811-2-1, 168 hours at 60°C |
| ambient temperature (operation) |
-25°C ... 80°C (cable, fixed installation) |
| -10°C ... 80°C (cable, movable installation) |